BMLS
Shear Beaml load cell, truck scale load cell
OIML approval Protection grade: IP68
Description
CAPACITY T 10, 20, 25, 30
Sensitivity mV/V 2.0±0.004
Accuracy class C3 C2 0.05
Maximum number of load cell interval 3000 2000
Minimum load cell verification interval Emax/10000 Emax/7000
Combined error %F.S 0.02 0/023 0.05
Repeatability %F.S 0.01 0.015 0.03
Creep %F.S/30min ±0.0245 ±0.0245 ±0.05
Minimum dead load output return %F.S ±0.017 ±0.025 ±0.05
Temp. effect on min. dead load output %F.S/5 ±0.007 ±0.010 ±0.025
Temp. effect on sensitivity %F.S/5 ±0.007 ±0.009 ±0.025
Minimum dead load %Emax 1
Maximum safe overload %Emax 150
Ultimate overload %Emax 200
Supply voltage V 10~15 (DC/AC)
Zero balance &F.S ±1
Input resistance Ω 770~830
Output resistance Ω 697 ~ 706
Insulation resistance MΩ ≥5000
Compensated temperature range -10 ~ + 40
Operating temperature range -30 ~ + 70
Connect cable mm 6.7 * 15000
Method of connecting wire Input(*): Red Input(-): White
Output(+): Green Output(-): Blue
Shield: Yellow