Zemic B3G
Description
SPECIFICATIONS Accuracy class OIML R60 C3 Output sensitivity ( = FS ) mV/V 3.0 ± 0.008 Maximum capacity ( Emax ) t 0.05/0.1 0.25/0.5/1/2.5 5/7.5/10 Maximum number of load cell intervals ( nLC ) 3000 Ratio of minimum LC verification interval Y = Emax / vmin 7000 10000 12000 Combined Error %FS ± 0.0200 Minimum dead load kg 0 Safe overload of Emax 150% Ultimate overload of Emax 300% Zero balance of FS ± 1.0% Excitation, recommended voltage V 5~12 Excitation maximum V 18 Terminal resistance, input 430±50 Terminal resistance, output 351 ± 2 Insulation impedance MΩ 5000 ( at 50VDC ) Temperature range, compensated °C -10 ~+40 Temperature range, operating °C -35 ~ +65 Material elements stainless steel Ingress Protection (according to EN 60529) IP67 ATEX classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
FEATURES Stainless steel IP67 “S” type load cell Tension and compression applications Suitable for hanging, hopper and other weighing devices Also available in imperial capacities and dimensions