Zemic H3

Zemic H3 load cells are available in the capacities 25kg to 30t and 100lb to 20klb. Alloy steel, sealed by adhesive inside, oil-proof, waterproof and anti-corrosion, suitable for all kinds of environments. S beam design, tension and/or compression loading possible, easy installation, suitable for crane scale, mechanical conversion scale, hopper scale and other electronic weighing devices. Safe and anti-explosive product, can be used in atrocious environment and hazardous areas.

Description

SPECIFICATIONS        
Capacityt0.025 / 0.05 / 0.1 / 0.15 / 0.2 / 0.25 / 0.3 / 0.5 / 0.6 / 0.75 / 1 / 1.5 / 2 / 2.5 / 3 / 5 / 7.5 / 10 / 15 / 20 / 30
lb100 / 200 / 250 / 300 / 500 / 750 / 1K / 1.5K / 2K / 2.5K / 3K / 5K / 10K / 15K / 20K
AccuracyC2C3C4A5SA5mB10SB10M
ApprovalOIML
R60 C3
OIML
R60 C4
Maximum
number of
verification
intervals
n max200030004000500050001000010000
Minimum
load cell
verification
interval
v minEmax
/5000
Emax
/10000
Emax
/14000
Emax
/15000
Emax
/15000
Emax
/10000
Emax
/10000
Combined
error
%FS±0.030±0.020±0.018±0.018±0.026±0.035±0.050
Creep%FS
/30min
±0.024±0.016±0.012±0.012±0.017±0.030±0.040
Temperature
effect
on sensitivity
%FS/10℃±0.017±0.011±0.009±0.009±0.013±0.030±0.040
Temperature
effect
on zero
%FS/10℃±0.023±0.015±0.010±0.010±0.014±0.030±0.020
Output
sensitivity
mv/v2.0 ± 0.004 (Metric) 3.0 ± 0.008 (Imperial)
Input
resistance
350±3.5
Output
resistance
351 ± 2.0
Insulation
resistance
5000 (50V DC)
Zero balance%FS1.5 (Metric) 1.0 (Imperial)
Temperature,
compensated
-10~+40
Temperature,
operating
-35 ~ +65
Excitation,
Recommended
V5~12(DC)
Excitation,
Max
V18 (DC)
Safe
overload
%FS150
Ultimate overload%FS300

Brosur