ZEMIC H6G
Description
Description
- Nickel plated alloy steel IP66 single point load cell
- Suitable for single or double load cell structured platform scales
- Maximum platform size: 600 x 600 mm
Accuracy class C3 Output sensitivity ( = FS ) mV/V 2.0 ± 0.2 Maximum capacity ( Emax ) kg 100, 150, 200, 250, 300, 500, 600 Max. number of load cell intervals nLC 3000 Ratio of min. LC verification interval Y = Emax / vmin 7500 Combined Error %FS ≤± 0.0230 Minimum dead load of Emax 0% Safe overload of Emax 150 % Ultimate overload of Emax 300 % Zero balance of FS < ± 1.0 % Excitation, recommended voltage V 5 ~ 12 Excitation maximum V 18 Input resistance Ω 384 ± 4 Output resistance Ω 351 ± 2 Insulation resistance MΩ ≥5000 ( at 50VDC ) Compensated temperature °C -10 ~+40 Operating temperature °C -35 ~ +65 Storage temperature °C -40 ~ +70 Element material Nickel plated alloy steel Ingress Protection (acc. to EN 60529) IP66 Recommended torque on fixation Nm M8: 25 ATEX classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4