ZEMIC H6G

Description

Description

  • Nickel plated alloy steel IP66 single point load cell
  • Suitable for single or double load cell structured platform scales
  • Maximum platform size: 600 x 600 mm

Accuracy classC3
Output sensitivity ( = FS )mV/V2.0 ± 0.2
Maximum capacity ( Emax )kg100, 150, 200, 250, 300, 500, 600
Max. number of load cell intervalsnLC3000
Ratio of min. LC verification intervalY = Emax / vmin7500
Combined Error%FS≤± 0.0230
Minimum dead loadof Emax0%
Safe overloadof Emax150 %
Ultimate overloadof Emax300 %
Zero balanceof FS< ± 1.0 %
Excitation, recommended voltageV5 ~ 12
Excitation maximumV18
Input resistanceΩ384 ± 4
Output resistanceΩ351 ± 2
Insulation resistance≥5000 ( at 50VDC )
Compensated temperature°C-10 ~+40
Operating temperature°C-35 ~ +65
Storage temperature°C-40 ~ +70
Element materialNickel plated alloy steel
Ingress Protection (acc. to EN 60529)IP66
Recommended torque on fixationNmM8: 25
ATEX classification (optional)II1G Ex ia II1C T4II1D Ex iaD 20 T73°CII3G nL IIC T4