Zemic HM8C

Description

Accuracy classC3
Output sensitivity (=FS)mV/V2.0 ± 0.004
Maximum capacity (Emax)t0.5, 1, 1.5, 2, 3, 5, 10
Maximum number of load cell intervals (nlc)3000
Ratio of minimum LC verification interval Y = Emax / Vmin7500
Combined Error%FS≤±0.020
Safe overloadof Emax150%
Ultimate overloadof Emax300%
Zero balanceof FS≤±1.5%
Excitation, recommended voltageV5 ~ 12
Excitation maximumV18
Terminal resistance, input350 ± 3.5
Terminal resistance, output351 ± 2.0
Insulation impedanceMΩ≥ 5000 (at 50VDC)
Temperature range, compensated°C-10~+40
Temperature range, operating°C-35~+65
Element materialAlloy steel
Ingress Protection ( according to EN 60529)IP68
Recommended torque on fixation boltsNmM12: 100 M18: 200 M24: 700
ATEX classification (optional)II1G Ex ia IICT4II1D Ex iaD 20 T73°CII3G nL IIC T4