  • Aluminum-alloy IP65 single point load cell
  • Colorless anodized
  • Suitable for pricing scales, bench scales, etc.
  • Maximum platform size: 250 x 350 mm

Accuracy classC3OIML R60 C3OIML R60 C4OIML R60 C5
Output sensitivity ( = FS )mV/V1.8 ± 0.22.0 ± 0.2
Maximum capacity ( Emax )kg2.53, 5, 6, 8, 10, 15, 20, 30, 35, 40, 50
Max. number of load cell intervalsnLC3000300040005000
Ratio of min. LC verification intervalY = Emax /7000100001500020000
Combined Error%FS≤± 0.0230≤± 0.0175≤± 0.0140
Minimum dead loadof Emax0%
Safe overloadof Emax150 %
Ultimate overloadof Emax300 %
Zero balanceof FS< ± 2.0 %
Excitation, recommended voltageV5 ~ 12
Excitation maximumV18
Input resistanceΩ409 ± 6
Output resistanceΩ350 ± 3
Insulation resistance≥5000 ( at 50VDC )
Compensated temperature°C-10…+40
Operating temperature°C-35…+65
Storage temperature°C-40…+70
Element materialAluminium
Ingress Protection (acc. to EN 60529)IP65
Recommended torque on fixation boltsNm< 30kg: 6 < 30kg: 6