ZEMIC L6G

Description

Description

  • Aluminium-alloy IP65 single point load cell
  • Colourless anodized
  • Suitable for single and double load cells structured
    platform scales
  • Maximum platform size: 600 x 600 mm
  • A 1000 Ohm type available (R1) but is excluded from OIML

Accuracy class OIML R60 C3OIML R60 C4
Output sensitivity ( = FS )mV/V2.0 ± 0.2
Maximum capacity ( Emax )kg50, 100, 150, 200, 250, 300, 500, 600150, 200, 250, 300, 500, 600
Max.number of load cell intervalsnLC30004000
Ratio of min. LC verification intervalY = Emax / vmin1000015000
Combined Error%FS≤± 0.0230≤± 0.0175
Minimum dead loadof Emax0%
Safe overloadof Emax150 %
Ultimate overloadof Emax300 %
Zero balanceof FS< ± 2.0 %
Excitation, recommended voltageV5 ~ 12
Excitation maximumV18
Input resistanceΩ406 ± 6
Output resistanceΩ350 ± 3
Insulation resistance≥5000 ( at 50VDC )
Compensated temperature°C-10 ~+40
Operating temperature°C-35 ~ +65
Storage temperature°C-40 ~ +70
Element materialAluminium
Ingress Protection (acc. to EN 60529)IP65
Recommended torque on fixation boltsNmM8:25

Download Brosur